3500/40M 135489-04 Bently Nevada Proximitor I/O Imodyuli
Ulwazi ngokubanzi
Ukwenziwa | Ngokucacileyo Nevada |
Inombolo yomba | 3500/40M |
Inombolo yenqaku | 135489-04 |
Uthotho | 3500 |
Imvelaphi | eMelika (US) |
Ubungakanani | 85*140*120(mm) |
Ubunzima | 1.2kg |
Inombolo yoMrhumo weCustoms | 85389091 |
Uhlobo | I-Proximitor I/O Imodyuli |
Idatha eneenkcukacha
3500/40M 135489-04 Bently Nevada Proximitor I/O Imodyuli
I-3500 Izithintelo zangaphakathi ziyi-intersentially interfaces ezikhuselekileyo ezibonelela ngokukhuselwa kokuqhuma kweenkqubo ze-transducer eziqhagamshelwe ngokuthe ngqo kwi-3500 Machinery Protection System.
Izithintelo zangaphakathi zihambelana ngokupheleleyo neNkqubo ye-3500 kwaye zibonelela ngesisombululo esifanelekileyo kunye neendleko ezifanelekileyo zokufaka zonke iintlobo zeenkqubo ze-transducer ngaphakathi kwendawo enobungozi.
Qaphela:Ngokungafaniyo nemiqobo yangaphandle, i-3500 Internal Barriers iyinxalenye ye-3500 System kwaye ayiyi kuthoba umgangatho wokusebenza kwenkqubo.
Isikhokelo sokuFakelo:
Izithintelo zangaphakathi ze-rack ye-3500 zifakwe kwiimodyuli ezikhethekileyo ze-I / O.
Ezi zithintelo zibonelela ngokukhuselwa kokuqhuma kweenkqubo zenzwa ezixhunywe kwinkqubo ye-3500. I-Intrinsically Safe (IS) Grounding Module ibonelela nge-IS uqhagamshelo lomhlaba ngokusebenzisa i-3500 system backplane.
IS Imodyuli yokuQalisa ifuna indawo yemodyuli ye-I/O ezinikeleyo kwaye iyakwalela ukusetyenziswa kwesi sikhundla sokubeka iliso kwezinye iimodyuli zenkqubo ye-3500. Oku kunciphisa umgangatho we-19-intshi ye-rack ukuya kwiindawo ezili-13 zokubeka iliso. Ukongezelela, ezininzi iinketho zokunyuka azifumaneki xa izithintelo zangaphakathi zifakwe kwi-rack ye-3500.
Ukuhlohla okuTsha kweRakhi:
I-rack efanayo inokuqulatha zombini umqobo wangaphakathi kunye neentlobo zemodyuli ze-I / O eziqhelekileyo ngaphandle kokuphazamisa ukuhlukaniswa phakathi kwe-wiring yendawo eyingozi kunye nekhuselekileyo.
Inketho yokuphelisa yangaphandle ayifumaneki kwiimodyuli ze-I / O ezinezithintelo zangaphakathi ngenxa yokuba iziqinisekiso zendawo ezinobungozi azivumeli ukusetyenziswa kwee-wiring ezikhuselekileyo zangaphakathi kwiindibano zentambo ze-multi-conductor.
Iimonitha eziqulethe i-Triple Modular Redundant (TMR) ukhetho lwe-rack alukwazi ukusebenzisa iimodyuli ze-I / O zesithintelo sangaphakathi kuba ukudibanisa abenzi boluvo kwiingeniso ezininzi ze-I / O zemodyuli kuphazamisa ukunyaniseka kwenkqubo ye-IS.